The LCI132 Series Process Indicators Offer Flexibility, And Value In A Low Cost, Compact 1/32 DIN Package. This Family Of Indicators Offers Input Availability For Most Types Of Process Measurement.
The LCI 132 Has A 7.62 Mm( 0.3") High Display. The Shallow Depth Of These Full Size Panel Meters Allows Installation In Panels Only 70 Mm (2.76") Deep With Room To Spare.
Inputs Are Available For Process (0 To 10 V, 4 To 20 MA), AC Volts, AC Amps, DC Volts, And DC Amps.
LCI32-0x
Input Volts (DC)
Input Amperes
Range: ±200V ±20V ±10V ±100 MV ±20 MA
Resolution: 0.1V 0.01V 1 MV 0.1 MV 0.01 MA
Input Impedance
Volts: 1 Mohms
MV: 100 Mohms
MA: 12.1 Ohms
LCI32-1x
Input Volts (DC)
Input Amperes
Range AC: 600.0 100.0 5.000 1.000
Range DC: -199.9 +600.0 ±100.0 -1.999 +5.000±1.000
Resolution: 0.1V 1 MA
Input Impedance
Volts: 3 Mohms (106)
Amp: 12 Mohms (10-3)
Accuracy At 23°C ±5°C
100/600 VDC 1/5 ADC; 600V/5AAc: ±(0.2% Reading + 3 Digits)
100V/1AAc: ±(0.4% Reading + 4 Digits)
Temperature Coefficient: 100 Ppm/°C
Warm Up: 5 Minutes
Power Supply And Fuses (DIN 4661) (Not Supplied):
LCI132-X0:
85-265 VAC 50/60 Hz And 100-300 VDC: Fuse: 0.1A/250V
LCI132-X1:
21-53 VAC 50/60 Hz And 10.7-70 VDC: Fuse: 0.5A/250V
Display
Range: -1999 To 9999 (DC) 0 To 9999 (AC)
Type: 4 Red Digits 10 Mm
Reading Rate: 4/S
Overflow Indication: OVR
Environmental
Operating Temperature: -10 To 60°C
Storage Temperature: -25 To 85°C
Relative Humidity (Non-Condensed):<95% @ 40°C
Panel Sealing: NEMA 4X (IP65)