----------------------- Page 1-----------------------

      Human Interleukin 10(IL-10)

                              ELISA Kit

 

                        Catalog No. CSB-E04593h

 

                                       (96T)

 

    This immunoassay kit allows for the in vitro quantitative determination of human

 

    IL-10 concentrations in serum, plasma and other biological fluids.

 

    Expiration date     six months from the date of manufacture

 

    FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.

 

                                           1


----------------------- Page 2-----------------------

INTRODUCTION

 

Interleukin-10   (IL-10), also   known   as human  cytokine   synthesis   inhibitory

 

factor (CSIF), is an anti-inflammatory cytokine. This cytokine is produced

 

primarily     by   monocytes       and    to  a  lesser    extent    by   lymphocytes.      This

 

cytokine   has   pleiotropic   effects   in   immunoregulation   and   inflammation.   It

 

down-regulates   the   expression   of   Th1   cytokines,   MHC  class   II   antigens,

 

and   costimulatory   molecules   on   macrophages.   It   also   enhances   B   cell

 

survival,   proliferation,   and   antibody   production.   This   cytokine   can   block

 

NF-κB activity, and is involved in the regulation of the JAK-STAT signaling

 

pathway. Knockout studies in mice suggested the function of this cytokine

 

as an essential immunoregulator in the intestinal tract. A study in mice has

 

shown that interleukin-10 is also produced by mast cells, counteracting the

 

inflammatory effect that these cells have at the site of an allergic reaction.

 

PRINCIPLE OF THE ASSAY

 

The     microtiter    plate   provided    in  this   kit  has   been   pre-coated       with   an

 

antibody   specific   to   IL-10   Standards   or   samples   are   then   added   to   the

 

appropriate       microtiter    plate    wells   with    a   biotin-conjugated       polyclonal

 

antibody       preparation      specific     for   IL-10    and     Avidin    conjugated       to

 

Horseradish        Peroxidase      (HRP)     is  added     to  each    microplate     well   and

 

incubated. Then a TMB (3,3'5, 5' tetramethyl-benzidine) substrate solution

 

is added to each well. Only those wells that contain IL-10, biotin-conjugated

 

antibody and enzyme-conjugated Avidin will exhibit a change in color. The

 

enzyme-substrate reaction is terminated by the addition of a sulphuric acid

 

solution   and   the   color   change   is   measured   spectrophotometrically   at   a

 

wavelength of 450 nm ± 2 nm. The concentration of IL-10 in the samples is

 

then   determined   by   comparing   the   O.D.   of   the   samples   to   the   standard

 

curve.

 

                                                2


----------------------- Page 3-----------------------

DETECTION RANGE

 

12.5   pg/ml-800   pg/ml.   The   standard   curve   concentrations   used   for   the

 

ELISA’s   were   800   pg/ml,   400   pg/ml,   200   pg/ml,   100   pg/ml,   50   pg/ml,   25

 

pg/ml, 12.5 pg/ml.

 

SPECIFICITY

 

This assay recognizes recombinant and natural human IL-10 No significant

 

cross-reactivity or interference was observed.

 

SENSITIVITY

 

The minimum detectable dose of human IL-10 is typically less than 3 pg/ml.

 

The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined

 

as the lowest protein concentration that could be differentiated from zero.

 

MATERIALS PROVIDED

 

               Reagent                                      Quantity

 

               Assay plate                                       1

 

               Standard                                          2

 

               Sample Diluent                               1 x 20 ml

 

               Biotin-antibody Diluent                      1 x 10 ml

 

               HRP-avidin Diluent                           1 x 10 ml

 

               Biotin-antibody                              1 x 120l

 

               HRP-avidin                                   1 x 120l

 

                                                            1 x 20 ml

               Wash Buffer

                                                         (25×concentrate)

 

               TMB Substrate                                1 x 10 ml

 

               Stop Solution                                1 x 10 ml

 

                                           3


----------------------- Page 4-----------------------

STORAGE

 

1.   Unopened   test   kits   should   be   stored   at   2-8°C   upon   receipt   and   the

 

    microtiter plate should be kept in a sealed bag. The test kit may be used

 

    throughout      the   expiration    date   of   the  kit,  provided    it  is  stored   as

 

    prescribed above. Refer to the package label for the expiration date.

 

2.   Opened test plate should be stored at 2-8°C in the aluminum foil bag

 

    with desiccants to minimize exposure to damp air. The kits will remain

 

    stable until the expiring date shown, provided it is stored as prescribed

 

    above.

 

3.   A   microtiter   plate   reader   with   a   bandwidth   of   10   nm   or   less   and   an

 

    optical   density   range   of   0-3   OD   or   greater   at   450nm   wavelength   is

 

    acceptable for use in absorbance measurement.

 

REAGENT PREPARATION

 

Bring all reagents to room temperature before use.

 

1.   Wash Buffer          If crystals have formed in the concentrate, warm up to

 

     room   temperature   and   mix   gently   until   the   crystals  have   compley

 

     dissolved. Dilute 20 ml of Wash Buffer Concentrate  into deionized or

 

     distilled water to prepare 500 ml of Wash Buffer.

 

2.   Standard        Centrifuge   the   standard   vial   at   6000-10000rpm   for       30s.

 

     Reconstitute       the Standard       with   1.0   ml   of Sample       Diluent.     This

 

     reconstitution      produces     a   stock   solution    of  800    pg/ml.   Allow    the

 

     standard to sit for a minimum of 15 minutes with gentle agitation prior to

 

     making   serial     dilutions.   The   undiluted    standard     serves   as   the  high

 

     standard (800 pg/ml). The Sample Diluent serves as the zero standard

 

     (0 pg/ml). Prepare fresh for each assay. Use within 4 hours and discard

 

     after use.

 

                                               4


----------------------- Page 5-----------------------

3.   Biotin-antibody         Centrifuge     the  vial  before   opening.    Dilute   to  the

 

     working       concentration        using    Biotin-antibody          Diluent(1:100),

 

     respectively.

 

4.   HRP-avidin        Centrifuge the vial before opening. Dilute to the working

 

     concentration using HRP-avidin Diluent(1:100), respectively.

 

Precaution: The Stop Solution provided with this kit is an acid solution. Wear

 

             eye, hand, face, and clothing protection when using this material.

 

OTHER SUPPLIES REQUIRED

 

      Microplate   reader   capable   of   measuring   absorbance  at   450   nm,   with

 

     the correction wavelength set at 540 nm or 570 nm.

 

      Pipettes and pipette tips.

 

      Deionized or distilled water.

 

      Squirt bottle, manifold dispenser, or automated microplate washer.

 

      An incubator which can provide stable incubation conditions up to

 

     37°C±0.5°C.

 

SAMPLE COLLECTION AND STORAGE

 

     Serum      Use a serum separator tube (SST) and allow samples to clot

 

     for 30 minutes before centrifugation for 15 minutes at 1000 g. Remove

 

     serum and assay immediay or aliquot and store samples at -20°C.

 

     Centrifuge   the   sample   again   after   thawing   before   the   assay.   Avoid

 

     repeated freeze-thaw cycles.

 

     Plasma       Collect     plasma     using   citrate,  EDTA,     or   heparin    as   an

 

     anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of

 

     collection.   Assay   immediay   or   aliquot   and   store  samples   at   -20°C.

 

     Centrifuge   the   sample   again   after   thawing   before   the   assay.   Avoid

 

     repeated freeze-thaw cycles.

 

Note: Grossly hemolyzed samples are not suitable for use in this assay.

 

                                              5


----------------------- Page 6-----------------------

ASSAY PROCEDURE

 

Bring     all  reagents    and    samples     to  room     temperature    before     use.   It  is

recommended that all samples, standards, and controls be assayed in duplicate.

All   the   reagents   should   be   added   directly   to   the   liquid   level   in   the   well.   The

pipette should avoid contacting the inner wall of the well.

 

 1.   Add   100l   of   Standard,   Blank,   or   Sample   per   well.   Cover   with   the

 

     adhesive strip. Incubate for 2 hours at 37°C.

 

 2.   Remove the liquid of each well, don’t wash.

 

 3.   Add 100l of Biotin-antibody working solution to each well. Incubate

 

     for   1   hour   at  37°C.   Biotin-antibody   working           solution    may    appear

 

     cloudy.   Warm   up   to   room   temperature   and   mix   gently  until   solution

 

     appears uniform.

 

 4.   Aspirate each well and wash, repeating the process three times for a

 

     total of three washes. Wash: Fill each well with Wash Buffer (200l) and

 

     let   it  stand for  2  minutes, then   remove   the   liquid  by flicking  the  plate

 

     over a sink. The remaining drops are removed by patting the plate on a

 

     paper   towel.   Complete   removal   of   liquid   at   each   step   is   essential   to

 

     good performance.

 

 5.   Add   100l   of  HRP-avidin   working   solution   to   each   well.   Cover   the

 

     microtiter plate with a new adhesive strip. Incubate for 1 hour at 37°C.

 

 6.   Repeat the aspiration and wash three times as step 4.

 

 7.   Add 90l of TMB Substrate to each well. Incubate for 10-30 minutes at

 

     37°C.     Keeping     the   plate   away     from   drafts    and   other   temperature

 

     fluctuations in the dark.

 

 8.   Add    50l    of  Stop    Solution   to     each    well  when     the  first   four  wells

 

     containing the highest concentration of standards develop obvious blue

 

     color. If color change does not appear uniform, gently tap the plate to

 

     ensure thorough mixing.

 

 9.   Determine the optical density of each well within 30 minutes, using a

 

     microplate reader set to 450 nm.

 

                                                6


----------------------- Page 7-----------------------

CALCULATION OF RESULTS

 

Using   the   professional   soft   "Curve   Exert   1.3"   to   make   a   standard   curve   is

 

recommended, which can be downloaded from our web.

 

Average the duplicate readings for each standard, control, and sample and

 

subtract the average zero standard optical density. Create a standard curve

 

by reducing the data using computer software capable of generating a four

 

parameter logistic (4-PL) curve-fit. As an alternative, construct a standard

 

curve   by   plotting   the   mean   absorbance   for   each   standard   on   the   y-axis

 

against the concentration on the x-axis and draw a best fit curve through the

 

points on the graph. The data may be linearized by plotting the log of the

 

IL-10 concentrations versus the log of the O.D. and the best fit line can be

 

determined       by    regression     analysis.    This   procedure      will  produce      an

 

adequate but less precise fit of the data. If samples have been diluted, the

 

concentration       read   from   the   standard    curve    must   be  multiplied     by  the

 

dilution factor.

 

LIMITATIONS OF THE PROCEDURE

 

      The kit should not be used beyond the expiration date on the kit label.

 

      Do not mix or substitute reagents with those from other lots or sources.

 

      It is important that the Standard Diluent selected for the standard curve

 

     be consistent with the samples being assayed.

 

      If samples generate values higher than the highest standard, dilute the

 

     samples with the appropriate Standard Diluent and repeat the assay.

 

      Any    variation    in  Standard      Diluent,    operator,    pipetting    technique,

 

     washing   technique,   incubation   time   or   temperature,  and   kit   age   can

 

     cause variation in binding.

 

                                               7


----------------------- Page 8-----------------------

      This assay is designed to eliminate interference by soluble receptors,

 

     binding proteins, and other factors present in biological samples. Until

 

     all   factors   have    been    tested    in  the   Quantikine     Immunoassay,         the

 

     possibility of interference cannot be excluded.

 

TECHNICAL HINTS

 

      Centrifuge vials before opening to collect contents.

 

      When mixing or reconstituting protein solutions, always avoid foaming.

 

      To avoid cross-contamination, change pipette tips between additions of

 

     each standard level, between sample additions, and between reagent

 

     additions. Also, use separate reservoirs for each reagent.

 

      When   using   an   automated   plate   washer,   adding   a   30  second   soak

 

     period   following   the   addition   of   wash   buffer,   and/or   rotating   the   plate

 

     180 degrees between wash steps may improve assay precision.

 

      To   ensure   accurate   results,   proper   adhesion   of   plate   sealers   during

 

     incubation steps is necessary.

 

      Substrate Solution should remain colorless or light blue until added to

 

     the    plate.   Keep    Substrate     Solution    protected     from    light.  Substrate

 

     Solution   should   change   from   colorless   or   light   blue   to   gradations   of

 

     blue.

 

      Stop Solution should be added to the plate in the  same order as the

 

     Substrate Solution. The color developed in the wells will turn from blue

 

     to   yellow   upon   addition   of   the   Stop   Solution. Wells  that   are   green   in

 

     color indicate that the Stop Solution has not mixed thoroughly with the

 

     Substrate Solution.

 

                                                8


----------------------- Page 9-----------------------

                 人白介素人白介素10(IL-10)酶聯(lián)免疫分析酶聯(lián)免疫分析

                 人白介素人白介素                  酶聯(lián)免疫分析酶聯(lián)免疫分析

 

                          試劑盒使用說(shuō)明書(shū)試劑盒使用說(shuō)明書(shū)

                          試劑盒使用說(shuō)明書(shū)試劑盒使用說(shuō)明書(shū)

 

本試劑盒僅供研究使用本試劑盒僅供研究使用

本試劑盒僅供研究使用本試劑盒僅供研究使用

 

產(chǎn)品編號(hào)產(chǎn)品編號(hào)::CSB-E04593h

產(chǎn)品編號(hào)產(chǎn)品編號(hào)::

 

檢測(cè)范圍檢測(cè)范圍::12.5 pg/ml-800 pg/ml,

檢測(cè)范圍檢測(cè)范圍::

 

zui低檢測(cè)限zui低檢測(cè)限::3 pg/ml

zui低檢測(cè)限zui低檢測(cè)限::

 

特異性特異性::本試劑盒可同時(shí)檢測(cè)天然或重組的人 IL-10,且與其他相關(guān)蛋白

特異性特異性::

無(wú)交叉反應(yīng)。

 

有效期有效期::6 個(gè)月

有效期有效期::

 

預(yù)期應(yīng)用預(yù)期應(yīng)用::ELISA 法定量測(cè)定人血清、血漿、細(xì)胞培養(yǎng)上清或其它相關(guān)生

預(yù)期應(yīng)用預(yù)期應(yīng)用::

物液體中IL-10 含量。

 

說(shuō)明說(shuō)明

說(shuō)明說(shuō)明

 

1   試劑盒保存:未開(kāi)封的試劑盒應(yīng)儲(chǔ)存于2-8℃;開(kāi)封后的酶標(biāo)板應(yīng)與干燥

    劑一起儲(chǔ)存于鋁箔袋中置于2-8℃保存。僅在此出儲(chǔ)存條件下,產(chǎn)品在有

    效期內(nèi)可正常使用。

2   濃洗滌液低溫保存會(huì)有鹽析出,稀釋時(shí)可在水浴中加溫助溶。

3   中、英文說(shuō)明書(shū)可能會(huì)有不一致之處,請(qǐng)以英文說(shuō)明書(shū)為準(zhǔn)。

4   剛開(kāi)啟的酶聯(lián)板孔中可能會(huì)含有少許水樣物質(zhì),此為正常現(xiàn)象,不會(huì)對(duì)實(shí)

    驗(yàn)結(jié)果造成任何影響。

 

實(shí)驗(yàn)原理實(shí)驗(yàn)原理

實(shí)驗(yàn)原理實(shí)驗(yàn)原理

 

     用純化的抗體包被微孔板,制成固相載體,往包被抗IL-10 抗體的微孔中

依次加入標(biāo)本或標(biāo)準(zhǔn)品、*化的抗IL-10 抗體、HRP 標(biāo)記的親和素,經(jīng)

過(guò)*洗滌后用底物TMB 顯色。TMB 在過(guò)氧化物酶的催化下轉(zhuǎn)化成藍(lán)色,

并在酸的作用下轉(zhuǎn)化成zui終的黃色。顏色的深淺和樣品中的IL-10 呈正相關(guān)。

用酶標(biāo)儀在450nm 波長(zhǎng)下測(cè)定吸光度 (OD 值),計(jì)算樣品濃度。

 

                                      9


----------------------- Page 10-----------------------

試劑盒組成及試劑配制試劑盒組成及試劑配制

試劑盒組成及試劑配制試劑盒組成及試劑配制

 

1.  酶聯(lián)板酶聯(lián)板(Assay plate ):                                      一塊(96 孔)。

    酶聯(lián)板酶聯(lián)板

2.  標(biāo)準(zhǔn)品標(biāo)準(zhǔn)品(Standard):                                          2 瓶(凍干品)。

    標(biāo)準(zhǔn)品標(biāo)準(zhǔn)品

3.  樣品稀釋液樣品稀釋液(Sample Diluent):                                  1×20ml/瓶。

    樣品稀釋液樣品稀釋液

4.  *標(biāo)記抗體稀釋液*標(biāo)記抗體稀釋液((Biotin-antibody Diluent):)             1×10ml/瓶。

    *標(biāo)記抗體稀釋液*標(biāo)記抗體稀釋液((                            ))

5.  辣根過(guò)氧化物酶標(biāo)記親和素稀釋液辣根過(guò)氧化物酶標(biāo)記親和素稀釋液((HRP-avidin Diluent)) 1×10ml/瓶。

    辣根過(guò)氧化物酶標(biāo)記親和素稀釋液辣根過(guò)氧化物酶標(biāo)記親和素稀釋液((                         ))

6.  *標(biāo)記抗體*標(biāo)記抗體((Biotin-antibody):)                 1×120l/瓶(1:100)。

    *標(biāo)記抗體*標(biāo)記抗體((                  ))

7.  辣根過(guò)氧化物酶標(biāo)記親和素辣根過(guò)氧化物酶標(biāo)記親和素((HRP-avidin):)            1×120l/瓶(1:100)。

    辣根過(guò)氧化物酶標(biāo)記親和素辣根過(guò)氧化物酶標(biāo)記親和素((                ))

8.  底物溶液底物溶液((TMB Substrate):)                                   1×10ml/瓶。

    底物溶液底物溶液((                 ))

9.  濃洗滌液濃洗滌液((Wash Buffer )) 1×20ml/瓶,使用時(shí)每瓶用蒸餾水稀釋25 倍。

    濃洗滌液濃洗滌液((               ))

10. 終止液終止液((Stop Solution):)                                     1×10ml/瓶。

    終止液終止液((                ))

 

需要而未提供的試劑和器材需要而未提供的試劑和器材

需要而未提供的試劑和器材需要而未提供的試劑和器材

 

1.  標(biāo)準(zhǔn)規(guī)格酶標(biāo)儀

2.  高速離心機(jī)

3.  電熱恒溫培養(yǎng)箱

4.  干凈的試管和Eppendof 管

5.  系列可調(diào)節(jié)移液器及吸頭,一次檢測(cè)樣品較多時(shí),用多通道移液器

6.  蒸餾水,容量瓶等

 

標(biāo)本的采集及保存標(biāo)本的采集及保存

標(biāo)本的采集及保存標(biāo)本的采集及保存

 

1.  血清:全血標(biāo)本請(qǐng)于室溫放置2 小時(shí)或4℃過(guò)夜后于1000g 離心20 分鐘,

    取上清即可立即檢測(cè);或進(jìn)行分裝,并將標(biāo)本放于-20℃或-80℃保存,但

    應(yīng)避免反復(fù)凍融。解凍后的樣品應(yīng)再次離心,然后檢測(cè)。

2.  血漿:可用EDTA 或肝素作為抗凝劑,標(biāo)本采集后30 分鐘內(nèi)于2   -   8°C

    1000 g 離心15 分鐘,取上清即可立即檢測(cè);或進(jìn)行分裝,并將標(biāo)本放于

    -20℃或-80℃保存,但應(yīng)避免反復(fù)凍融。解凍后的樣品應(yīng)再次離心,然后

    檢測(cè)。

3.  細(xì)胞培養(yǎng)物上清或其它生物標(biāo)本:1000g 離心20 分鐘,取上清即可立即

    檢測(cè);或進(jìn)行分裝,并將標(biāo)本放于-20℃或-80℃保存,但應(yīng)避免反復(fù)凍融。

    解凍后的樣品應(yīng)再次離心,然后檢測(cè)。

 

注:注:標(biāo)本溶血會(huì)影響zui后檢測(cè)結(jié)果標(biāo)本溶血會(huì)影響zui后檢測(cè)結(jié)果,因此溶血標(biāo)本不宜進(jìn)行此項(xiàng)檢測(cè),因此溶血標(biāo)本不宜進(jìn)行此項(xiàng)檢測(cè)。。

注注::標(biāo)本溶血會(huì)影響zui后檢測(cè)結(jié)果標(biāo)本溶血會(huì)影響zui后檢測(cè)結(jié)果,,因此溶血標(biāo)本不宜進(jìn)行此項(xiàng)檢測(cè)因此溶血標(biāo)本不宜進(jìn)行此項(xiàng)檢測(cè)。。

 

                                      10


----------------------- Page 11-----------------------

標(biāo)本的稀釋原則標(biāo)本的稀釋原則::

標(biāo)本的稀釋原則標(biāo)本的稀釋原則::

 

首先通過(guò)文獻(xiàn)檢索的方式了解待測(cè)樣本的大致含量,確定適當(dāng)?shù)南♂尡稊?shù)。

只有稀釋至標(biāo)準(zhǔn)曲線(xiàn)的范圍內(nèi),檢測(cè)的結(jié)果才是準(zhǔn)確的。稀釋的過(guò)程中,應(yīng)

做好詳細(xì)的記錄。zui后計(jì)算濃度時(shí),稀釋了“N”倍,標(biāo)本的濃度應(yīng)再乘以“N”。

 

標(biāo)準(zhǔn)品的稀釋原則標(biāo)準(zhǔn)品的稀釋原則::2 瓶,使用前于6000-10000rpm 離心30 秒。每

標(biāo)準(zhǔn)品的稀釋原則標(biāo)準(zhǔn)品的稀釋原則::

瓶臨用前以樣品稀釋液稀釋至1ml,蓋好后靜置10 分鐘以上,然后反復(fù)顛倒

/搓動(dòng)以助溶解,其濃度為800 pg/ml,做系列倍比稀釋后,分別稀釋800 pg/ml,

400 pg/ml, 200 pg/ml, 100 pg/ml, 50 pg/ml, 25 pg/ml, 12.5pg/ml,樣品稀釋

液直接作為標(biāo)準(zhǔn)濃度0   pg/ml,臨用前15 分鐘內(nèi)配制,用完丟棄,下次檢測(cè)

使用新鮮配置的標(biāo)準(zhǔn)品。

 

如配制400   pg/ml 標(biāo)準(zhǔn)品:取0.5ml  (不要少于0.5ml)800   pg/ml 的上述標(biāo)

準(zhǔn)品加入含0.5ml 樣品稀釋液的Eppendorf 管中,混勻即可,其余濃度以此

類(lèi)推。

 

*標(biāo)記抗體的稀釋原則*標(biāo)記抗體的稀釋原則::

*標(biāo)記抗體的稀釋原則*標(biāo)記抗體的稀釋原則::

 

打開(kāi)瓶蓋前請(qǐng)離心,收集瓶壁上的溶液。臨用前以*標(biāo)記抗體稀釋液稀

釋?zhuān)♂屒案鶕?jù)預(yù)先計(jì)算好的每次實(shí)驗(yàn)所需的總量配制 (每孔100l),實(shí)際

配制時(shí)應(yīng)多配制0.1-0.2ml。如10l *標(biāo)記抗體加990l *標(biāo)記抗體

稀釋液的比例配制,輕輕混勻,在使用前一小時(shí)內(nèi)配制。

 

辣根過(guò)氧化物酶標(biāo)記親和素的稀釋原則辣根過(guò)氧化物酶標(biāo)記親和素的稀釋原則::

辣根過(guò)氧化物酶標(biāo)記親和素的稀釋原則辣根過(guò)氧化物酶標(biāo)記親和素的稀釋原則::

 

打開(kāi)瓶蓋前請(qǐng)離心,收集瓶壁上的溶液。臨用前以辣根過(guò)氧化物酶標(biāo)記親和

素稀釋液稀釋?zhuān)♂屒案鶕?jù)預(yù)先計(jì)算好的每次實(shí)驗(yàn)所需的總量配制(每孔

100l),實(shí)際配制時(shí)應(yīng)多配制0.1-0.2ml。如10l 辣根過(guò)氧化物酶標(biāo)記親和素

加990l 辣根過(guò)氧化物酶標(biāo)記親和素稀釋液的比例配制,輕輕混勻,在使用

前一小時(shí)內(nèi)配制。

 

操作步驟操作步驟

操作步驟操作步驟

 

實(shí)驗(yàn)開(kāi)始前,請(qǐng)?zhí)崆芭渲煤盟性噭噭┗驑悠废♂寱r(shí),均需混勻,混勻

時(shí)盡量避免起泡。每次檢測(cè)都應(yīng)該做標(biāo)準(zhǔn)曲線(xiàn)。如樣品濃度過(guò)高時(shí),用樣品

稀釋液進(jìn)行稀釋?zhuān)允箻悠贩显噭┖械臋z測(cè)范圍。加樣時(shí),槍頭應(yīng)直接對(duì)

準(zhǔn)液面,切勿沿孔壁加樣。

 

                                      11


----------------------- Page 12-----------------------

1   加樣:分別設(shè)空白孔、標(biāo)準(zhǔn)孔、待測(cè)樣品孔。空白孔加樣品稀釋液100l,

    余孔分別加標(biāo)準(zhǔn)品或待測(cè)樣品100l,注意不要有氣泡,加樣將樣品加于

    酶標(biāo)板孔底部,盡量不觸及孔壁,輕輕晃動(dòng)混勻,酶標(biāo)板加上蓋或覆膜,

    37℃反應(yīng)120 分鐘。

    為保證實(shí)驗(yàn)結(jié)果有效性,每次實(shí)驗(yàn)請(qǐng)使用新的標(biāo)準(zhǔn)品溶液。

2   棄去液體,甩干,不用洗滌。每孔加*標(biāo)記抗體工作液 100l (取1l

    *標(biāo)記抗體加99l *標(biāo)記抗體稀釋液的比例配制,輕輕混勻,

    在使用前一小時(shí)內(nèi)配制),37℃,60 分鐘。

3   溫育60 分鐘后,棄去孔內(nèi)液體,甩干,洗板3 次,每次浸泡1-2 分鐘,

    200l/每孔,甩干。

4   每孔加辣根過(guò)氧化物酶標(biāo)記親和素工作液 (同*標(biāo)記抗體工作液)

    100l,37℃,60 分鐘。

5   溫育60 分鐘后,棄去孔內(nèi)液體,甩干,洗板5 次,每次浸泡1-2 分鐘,

    200l/每孔,甩干。

6   依序每孔加底物溶液90l,37℃避光顯色((30 分鐘內(nèi),此時(shí)肉眼可見(jiàn)標(biāo)

                                               ((

    準(zhǔn)品的前3-4 孔有明顯的梯度藍(lán)色,后3-4 孔顯色不明顯,即可終止)。

7   依序每孔加終止溶液50l,終止反應(yīng)(此時(shí)藍(lán)色立轉(zhuǎn)黃色)。終止液的加

    入順序應(yīng)盡量與底物液的加入順序相同。為了保證實(shí)驗(yàn)結(jié)果的準(zhǔn)確性,底

    物反應(yīng)時(shí)間到后應(yīng)盡快加入終止液。

8   用酶聯(lián)儀在450nm 波長(zhǎng)依序測(cè)量各孔的光密度 (OD 值)。 在加終止液

    后15 分鐘以?xún)?nèi)進(jìn)行檢測(cè)。

 

實(shí)驗(yàn)備注實(shí)驗(yàn)備注

實(shí)驗(yàn)備注實(shí)驗(yàn)備注

 

1.  用戶(hù)在初次使用試劑盒時(shí),應(yīng)將各種試劑管離心數(shù)分鐘,以便試劑集中到

    管底。

2.  每次實(shí)驗(yàn)留一孔作為空白調(diào)零孔,該孔不加任何試劑,只是zui后加底物溶

    液及終止液。測(cè)量時(shí)先用此孔調(diào)OD 值至零。

3.  為防止樣品蒸發(fā),試驗(yàn)時(shí)將反應(yīng)板放于鋪有濕布的密閉盒內(nèi),酶標(biāo)板加上

    蓋或覆膜。

4.  未使用完的酶標(biāo)板或者試劑,請(qǐng)于2-8℃保存。標(biāo)準(zhǔn)品、*標(biāo)記抗體

    工作液、辣根過(guò)氧化物酶標(biāo)記親和素工作液請(qǐng)依據(jù)所需的量配置使用。請(qǐng)

    勿重復(fù)使用已稀釋過(guò)的標(biāo)準(zhǔn)品、*標(biāo)記抗體工作液、或辣根過(guò)氧化物

    酶標(biāo)記親和素工作液。

5.  建議檢測(cè)樣品時(shí)均設(shè)雙孔測(cè)定,以保證檢測(cè)結(jié)果的準(zhǔn)確性。

 

                                      12


----------------------- Page 13-----------------------

洗板方法洗板方法

洗板方法洗板方法

手工洗板方法:吸去(不可觸及板壁)或甩掉酶標(biāo)板內(nèi)的液體;在實(shí)驗(yàn)臺(tái)上

鋪墊幾層吸水紙,酶標(biāo)板朝下用力拍幾次;將推薦的洗滌緩沖液至少0.3ml

注入孔內(nèi),浸泡1-2 分鐘。根據(jù)需要,重復(fù)此過(guò)程數(shù)次。

 自動(dòng)洗板:如果有自動(dòng)洗板機(jī),應(yīng)在熟練使用后再用到正式實(shí)驗(yàn)過(guò)程中。

 

計(jì)算計(jì)算

計(jì)算計(jì)算

 

請(qǐng)從我們的下載專(zhuān)業(yè)軟件"Curve Exert 1.3",并根據(jù)提示制作標(biāo)準(zhǔn)曲線(xiàn)。

以標(biāo)準(zhǔn)物的濃度為橫坐標(biāo)(對(duì)數(shù)坐標(biāo)),OD 值為縱坐標(biāo)(普通坐標(biāo)),在半對(duì)

數(shù)坐標(biāo)紙上繪出標(biāo)準(zhǔn)曲線(xiàn),根據(jù)樣品的OD 值由標(biāo)準(zhǔn)曲線(xiàn)查出相應(yīng)的濃度;

再乘以稀釋倍數(shù);或用標(biāo)準(zhǔn)物的濃度與OD 值計(jì)算出標(biāo)準(zhǔn)曲線(xiàn)的直線(xiàn)回歸方

程式,將樣品的OD 值代入方程式,計(jì)算出樣品濃度,再乘以稀釋倍數(shù),即

為樣品的實(shí)際濃度。

 

注意事項(xiàng)注意事項(xiàng)

注意事項(xiàng)注意事項(xiàng)

 

1.  本操作說(shuō)明適用于本操作說(shuō)明適用于48T 試劑盒試劑盒,, 48T 試劑盒中酶聯(lián)板試劑盒中酶聯(lián)板、標(biāo)準(zhǔn)品、標(biāo)準(zhǔn)品、*、*

    本操作說(shuō)明適用于本操作說(shuō)明適用于        試劑盒試劑盒,,      試劑盒中酶聯(lián)板試劑盒中酶聯(lián)板、、標(biāo)準(zhǔn)品標(biāo)準(zhǔn)品、、**

    標(biāo)記抗體及辣根過(guò)標(biāo)記抗體及辣根過(guò)氧化物酶標(biāo)記親和素減半氧化物酶標(biāo)記親和素減半。。

    標(biāo)記抗體及辣根過(guò)標(biāo)記抗體及辣根過(guò)氧化物酶標(biāo)記親和素減半氧化物酶標(biāo)記親和素減半。。

2.  當(dāng)混合蛋白溶液時(shí)應(yīng)盡量輕緩,避免起泡。

3.  洗滌過(guò)程非常重要,不充分的洗滌易造成假陽(yáng)性。

4.  一次加樣時(shí)間控制在5 分鐘內(nèi),如標(biāo)本數(shù)量多,推薦使用排槍加樣。

5.  請(qǐng)每次測(cè)定的同時(shí)做標(biāo)準(zhǔn)曲線(xiàn),做復(fù)孔。

6.  如標(biāo)本中待測(cè)物質(zhì)含量過(guò)高,請(qǐng)先稀釋后再測(cè)定,計(jì)算時(shí)請(qǐng)zui后乘以稀釋

    倍數(shù)。

7.  在配制標(biāo)準(zhǔn)品、檢測(cè)溶液工作液時(shí),請(qǐng)以相應(yīng)的稀釋液配制,不能混淆。

8.  底物請(qǐng)避光保存。

9.  不要用其它生產(chǎn)廠家的試劑替換試劑盒中的試劑。

 

                                      13


----------------------- Page 14-----------------------

Notes

 

                                                                            14


----------------------- Page 15-----------------------

                                                                            15


----------------------- Page 16-----------------------

                                                                            16


----------------------- Page 17-----------------------

                                                                            17


----------------------- Page 18-----------------------

                                                                            18


----------------------- Page 19-----------------------

                                                                            19


----------------------- Page 20-----------------------

 


環(huán)保在線(xiàn) 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.aboay.com,All rights reserved.

以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),環(huán)保在線(xiàn)對(duì)此不承擔(dān)任何保證責(zé)任。 溫馨提示:為規(guī)避購(gòu)買(mǎi)風(fēng)險(xiǎn),建議您在購(gòu)買(mǎi)產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

會(huì)員登錄

×

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

請(qǐng) 登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
主站蜘蛛池模板: 嘉定区| 巴彦淖尔市| 当阳市| 墨竹工卡县| 伊春市| 邵东县| 扎鲁特旗| 仁布县| 杭州市| 大安市| 江阴市| 安陆市| 社旗县| 松江区| 新竹市| 彭山县| 加查县| 会昌县| 团风县| 二手房| 西城区| 集安市| 东源县| 利川市| 武穴市| 岳普湖县| 贵溪市| 惠安县| 辉县市| 奉化市| 绥棱县| 师宗县| 田东县| 碌曲县| 杭州市| 丹东市| 花莲县| 邵东县| 丘北县| 淳安县| 桦南县|